Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters

Language
Document Type
Year range
1.
researchsquare; 2021.
Preprint in English | PREPRINT-RESEARCHSQUARE | ID: ppzbmed-10.21203.rs.3.rs-273466.v1

ABSTRACT

Shortages of personal protective equipment for use during the SARS-CoV-2 pandemic continue to be an issue among health-care workers globally. Extended and repeated use of N95 filtering facepiece respirators without adequate decontamination is of particular concern. Although several methods to decontaminate and re-use these masks have been proposed, logistic or practical issues limit adoption of these techniques. In this study, we propose and validate the use of the application of moist heat (70oC with humidity augmented by an open pan of water) applied by commonly available hospital (blanket) warming cabinets to decontaminate N95 masks. This report shows that a variety of N95 masks can be repeatedly decontaminated of SARS-CoV-2 over 6 hours moist heat exposure without compromise of their filtering function as assessed by standard fit and sodium chloride aerosol filtration efficiency testing. This approached can easily adapted to provide point-of-care N95 mask decontamination allowing for increased practical utility of mask recycling in the health care setting.

2.
biorxiv; 2020.
Preprint in English | bioRxiv | ID: ppzbmed-10.1101.2020.05.27.120402

ABSTRACT

The COVID-19 pandemic has affected most countries in the world. Studying the evolution and transmission patterns in different countries is crucial to implement effective strategies for disease control and prevention. In this work, we present the full genome sequence for 17 SARS-CoV-2 isolates corresponding to the earliest sampled cases in Mexico. Global and local phylogenomics, coupled with mutational analysis, consistently revealed that these viral sequences are distributed within 2 known lineages, the SARS-CoV-2 lineage A/G, containing mostly sequences from North America, and the lineage B/S containing mainly sequences from Europe. Based on the exposure history of the cases and on the phylogenomic analysis, we characterized fourteen independent introduction events. Additionally, three cases with no travel history were identified. We found evidence that two of these cases represent local transmission cases occurring in Mexico during mid-March 2020, denoting the earliest events described in the country. Within this Mexican cluster, we also identified an H49Y amino acid change in the spike protein. This mutation is a homoplasy occurring independently through time and space, and may function as a molecular marker to follow on any further spread of these viral variants throughout the country. Our results depict the general picture of the SARS-CoV-2 variants introduced at the beginning of the outbreak in Mexico, setting the foundation for future surveillance efforts. This work is the result of the collaboration of five institutions into one research consortium: three public health institutes and two universities. From the beginning of this work, it was agreed that the experimental leader of each institution would share the first authorship. Those were the criteria followed to assign first co-first authorship in this manuscript. The order of the other authors was randomly assigned. IMPORTANCEUnderstanding the introduction, spread and establishment of SARS-CoV-2 within distinct human populations is crucial to implement effective control strategies as well as the evolution of the pandemics. In this work, we describe that the initial virus strains introduced in Mexico came from Europe and the United States and the virus was circulating locally in the country as early as mid-March. We also found evidence for early local transmission of strains having the mutation H49Y in the Spike protein, that could be further used as a molecular marker to follow viral spread within the country and the region.


Subject(s)
COVID-19
3.
medrxiv; 2020.
Preprint in English | medRxiv | ID: ppzbmed-10.1101.2020.04.05.20049346

ABSTRACT

The response to the COVID19 epidemic is generating severe shortages of personal protective equipment around the world. In particular, the supply of N95 respirator masks has become severely depleted with supplies having to be rationed and health care workers having to use masks for prolonged periods in many countries. We sought to test the ability of 4 different decontamination methods including autoclave treatment, ethylene oxide gassing, ionized hydrogen peroxide fogging and vaporized hydrogen peroxide exposure to decontaminate 4 different N95 masks of experimental contamination with SARS-CoV-2 or vesicular stomatitis virus as a surrogate. In addition, we sought to determine whether masks would tolerate repeated cycles of decontamination while maintaining structural and functional integrity. We found that one cycle of treatment with all modalities was effective in decontamination and was associated with no structural or functional deterioration. Vaporized hydrogen peroxide treatment was tolerated to at least 5 cycles by masks. Most notably, standard autoclave treatment was associated with no loss of structural or functional integrity to a minimum of 10 cycles for the 3 pleated mask models. The molded N95 mask however tolerated only 1 cycle. This last finding may be of particular use to institutions globally due to the virtually universal accessibility of autoclaves in health care settings.


Subject(s)
COVID-19 , Vesicular Stomatitis
SELECTION OF CITATIONS
SEARCH DETAIL